Hydraulic Component fluid cleanliness requirements & Fluid type selection guide |
The following components should operate in the fluid cleanliness levels indicated or better |
Component Type |
Operating pressures |
<1500 psi |
1500 - 2500 psi |
>2500 psi |
ISO 4406 Cleanliness required |
Servo Valve |
16/14/12 |
15/13/11 |
14/12/10 |
Proportional Valve |
17/15/12 |
16/14/12 |
15/13/11 |
Variable Volume Pump |
17/16/13 |
17/15/12 |
16/14/12 |
Cartridge Valve |
18/16/14 |
17/16/13 |
17/15/12 |
Fixed Piston Pump |
18/16/14 |
17/16/13 |
17/15/12 |
Vane Pump |
19/17/14 |
18/16/14 |
17/16/13 |
Pressure/Flow control Valve |
19/17/14 |
18/16/14 |
17/16/13 |
Solenoid Valve |
19/17/14 |
18/16/14 |
18/16/14 |
Gear Pump |
19/17/14 |
18/16/14 |
18/16/14 |
|
|
|
|
Suggested Fluid type |
AW |
AW - HVI |
HVI |
|
|
|
|
Legend
|
"AW" is standard Anti Wear Hydraulic fluid usually with a Viscosity Index of approx 100 + |
"HVI is High Viscosity Index Hydraulic fluid usually with a Viscosity Index of approx 150 + |
|
|
|
|
Please note ‚ the above fluid guide is a general guide under "normal" service conditions and should be read in conjunction with Equipment Manufacturers recommendations ‚ do not confuse the Viscosity Index with the ISO Viscosity rating of a fluid |